Brand Name : Shengtai Instrument

Model Number : SH106B

Certification : ASTMD 92

Place of Origin : China

MOQ : 1

Payment Terms : T/T

Supply Ability : 10000 sets/year

Delivery Time : 7-15 work days

Packaging Details : wooden case

Working power supply : AC220V±10%, 50Hz

Temperature measurement : room temperature ~ 400℃; Repeatability: flash point ≤150℃ error ±2℃ flash point ≥150℃ error ±3℃ Resolution: 0.1℃; Precision: 0.5%;

Heating speed : in line with GB/T3536 ASTM D92 standard; About Heating rate from 5 to 17 C per min

ignition mode : electronic ignition, flame 3㎜~4㎜

ambient temperature : (10~40)℃

relative humidity : ≤80%

Boundary dimension : 430 * 380 * 520 (mm), about 15kg

Contact Now

Fully Automatic Cleveland Open Flash Point Tester ASTMD92 Lubricating Oil Rt ~ 400 ℃

Fully Automatic Flash Point Cleveland Open Cup ASTMD92 Lubricating Oil

SH106B automatic open flash point tester is designed and manufactured according to the standard GB/T 3536 and ASTMD 92 "Determination of flash point and ignition point of petroleum products (Cleveland open cup method)".

Instrument according to the standard method of heating, automatic rise and fall, automatic ventilation, automatic ignition, automatic display, automatic locking flash point value, automatic printing results.

Automatic open flash point tester for gear oil hydraulic oil turbine oil ASTMD 92 Cleveland open cup method

After the test can be automatically cooled, to achieve the full automation of the work process.

ASTM D92  Automatic Cleveland Open Cup Flash Point Tester

It has the advantages of accurate measurement, good repeatability, stable performance and simple operation. It also supports the determination of GB/T1671-2008 plasticizer flash point

Hydraulic Oil flash point tester ASTM D92

ASTM D92 Automatic Cleveland Open Cup Flash Point Tester for Oil Testing

ASTM D92 Automatic Engine Oil Open Cup Flash Point Tester

China Manufacturer Price Automatic Digital Portable Open Cup Type Oil Flash and Fire Point Tester

Automatic open flash point tester for Turbine oil standard ASTMD 92 GB/T3536 Cleveland open cup method

Product model SH106B
Product name Full-automatic open flash point tester
Manufacturer Shandong Shengtai Instrument Co., Ltd
Test items It can meet the requirements of petroleum, chemical, railway, aviation, electric power, commodity inspection and scientific research institutions for testing petroleum products
Compliance with standards National standard GB/T 3536 Petroleum Products - Determination of Flash Point and Flash Point (Cleveland Open Cup Method)
Simple technical features Full Chinese human-computer interface, no identification keyboard, with prompt menu and guided input function for parameters such as predictable temperature, sample number, atmospheric pressure, test date, etc.

instrument features

1. The instrument adopts color LCD large screen display, full Chinese man-machine dialogue interface, no identification keyboard, for the parameters such as pre-value temperature, sample label, atmospheric pressure, test date, with prompt menu, oriented input function.

2. Simulation tracking displays the function curve of temperature rise and test time. It has the function of Chinese wrong operation software to prompt modification, and the function of test date, test time and other parameters to prompt.

3. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value.

4. Differential detection, automatic correction of system deviation.

5. Scanning, detection and printing data are automatically completed, and the test arm automatically rises and falls.

6. Electronic ignition and forced air cooling

7, without automatic ignition of air source, improve the safety of the test

Main technical indexes and parameters

1, working power supply: AC220V±10%, 50Hz

2, temperature measurement: range: room temperature ~ 400℃;

Repeatability: flash point ≤150℃ error ±2℃ flash point ≥150℃ error ±3℃

Resolution: 0.1℃;

Precision: 0.5%;

3. Heating speed: in line with GB/T3536 standard;

4, ignition mode: electronic ignition, flame 3㎜~4㎜;

5, ambient temperature: (10~40)℃;

6, relative humidity: ≤80%;

7.Boundary dimension: 430 * 380 * 520 (mm), about 15kg

Working power supply AC220V±10%, 50Hz
Temperature measurement

room temperature ~ 400℃;

Repeatability: flash point ≤150℃ error ±2℃ flash point ≥150℃ error ±3℃

Resolution: 0.1℃;

Precision: 0.5%;

Heating speed

in line with GB/T3536 ASTM D92 standard;

About Heating rate from 5 to 17 C per min

ignition mode electronic ignition, flame 3㎜~4㎜
ambient temperature

(10~40)℃;

relative humidity ≤80%;
Boundary dimension: 430 * 380 * 520 (mm), about 15kg

Packing list

S/N Name Quantity Unit Remarks
1 Automatic opening flash point meter 1 set
2 Oil cup 1 piece
3 AC power cord 1 piece
4 Printing paper 1 piece
5 Operating instruction 1 piece
6 packing list 1 copy
7 Certificate of approval 1 copy


Product Tags:

Fully Automatic flash point cleveland open cup

      

Lubricating Oil flash point cleveland open cup

      

Cleveland flash point testing lab

      
China Fully Automatic Flash Point Cleveland Open Cup ASTMD92 Lubricating Oil wholesale

Fully Automatic Flash Point Cleveland Open Cup ASTMD92 Lubricating Oil Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shandong Shengtai instrument co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)